TRAINING CHILLER AND COOLING TOWER

TRAINING CHILLER AND COOLING TOWER

TRAINING CHILLER SYSTEM AND BASICS

TRAINING MECHANICAL ROOM SAFETY STANDARD

pelatihan CHILLER AND COOLING TOWER di jakarta

INTRODUCTION:

Chiller and cooling tower are used in HVAC, power plant and refrigeration system. Design and operation of the equipments are very important to know for an engineer. This course covers the fundamentals and practical applications for understanding of design and operation of the chiller and cooling tower. The comprehensive coverage of the basic theory, system analysis, optimization concept, and calculation methods to make this the most complete course available today in achieving an economical system.

TRAINING BENEFITS:

Enable to analyze and recommend the most effective solution available in operation and design for chiller and cooling tower. Enable to utilize energy as possible as saving for chiller and cooling tower system. Familiar and better understanding of all aspects relating to efficient chiller and cooling tower in commercial application.

WHO SHOULD ATTEND THIS TRAINING?:

Technicians
ME engineers
and other who responsible for selecting, mechanical equipments
MATERIAL OUTLINE  CHILLER AND COOLING TOWER:

Chiller System and Basics
Work Principle of Chiller
Piping Basics
Pumping Basics
Control Valve Basics
Loop Control Basics
Air-Cooled Chillers
Water-Cooled Chillers
Piping and Diversity
Chiller Construction and Safety
Dual Compressor Chillers
VFD Chillers
System Design Changes
Mechanical Room Safety Standard
Single Chiller System
Basic Operation and Arrangement of Chiller
Basic Components
Series Chillers System
Single Chiller Sequence of Operation
Parallel Chiller System
Parallel Chiller Sequence of Operation
Series Counterflow Chillers
Using VFD Chillers in Series Arrangements
System Comparison
Very Large Chiller Plants
PrimarySecondary Sequence of Operation
Chiller Cooling System
Water-Side Free Cooling
Direct Waterside Free Cooling
Parallel Waterside Free Cooling
Series Waterside Free Cooling
Waterside Free Cooling Design Approach
Waterside Free Cooling Sequence of Operation
Chilled Water Volume
Chilled Water Temperatures and Ranges
Minimum Chilled Water Volume
Estimating System Volume
Evaluating System Volume
Cooling Tower
Cooling Tower Types and Cooling Tower Systems
General Design Consideration
Cooling Tower Construction and Installation Requirements
Tower materials
Cooling Tower Design and Operation Consideration
Cooling Tower Water and Bleed-off Water Control
Improving Energy Efficiency of Cooling Towers
Hybrid Plants and Energy Saving
Heat Recovery and Templifiers
Load Profiles
Heat Recovery Chillers
Variable Primary Flow Design
Variable Primary Flow Sequence of Operation
Low Delta T Syndrome
Low Delta T Example
Low Delta T Syndrome Causes and Solutions

INSTRUCTOR :

DR. Ir. I Made Astina, M.Eng.  and Team

Jadwal Pelatihan Gemilang Training Tahun 2026 :

  • 7 – 8 Januari 2026
  • 11 – 12 Februari 2026
  • 4 – 5 Maret 2026
  • 8 – 9 April 2026
  • 6 – 7 Mei 2026
  • 10 – 11 Juni 2026
  • 8 – 9 Juli 2026
  • 5 – 6 Agustus 2026
  • 9 – 10 September 2026
  • 14 – 15 Oktober 2026
  • 4 – 5 November 2026
  • 2 – 3 Desember 2026
  • Catatan

 

Investasi dan Lokaspelatihan:

  • Yogyakarta, Hotel Neo Malioboro (7.500.000 IDR participant)
  • Jakarta, Hotel Amaris Tendean (7.500.000 IDR participant)
  • Bandung, Hotel Neo Dipatiukur (7.500.000 IDR participant)
  • Bali, Hotel Ibis Kuta(7.500.000 IDR participant)
  • Surabaya, Hotel Amaris, Ibis Style (7.500.000 IDR participant)
  • Lombok, Sentosa Resort (7.500.000 IDR participant)
  • Catatan : Apabila perusahaan membutuhkan paket in house training, anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan.

Fasilitas :

  • FREE Airport pickup service (Gratis Antar jemput HotelBandaraStasiunTerminal)
  • FREE Akomodasi Peserta ke tempat pelatihan .
  • Module Handout
  • FREE Flashdisk
  • Sertifikat
  • FREE Bag or bagpackers (Tas Training)
  • Training Kit (Dokumentasi photo, Blocknote, ATK, etc)
  • 2xCoffe Break & 1 Lunch, Dinner
  • FREE Souvenir Exclusive
  • Training room full AC and Multimedia

TRAINING CHILLER & COOLING TOWER DESIGN AND OPERATION

TRAINING CHILLER & COOLING TOWER DESIGN AND OPERATION

TRAINING CHILLER SYSTEM AND BASICS

TRAINING WORK PRINCIPLE OF CHILLER

pelatihan CHILLER & COOLING TOWER Design and Operation di jakarta

Chiller and cooling tower are used in HVAC, power plant and refrigeration system. Design and operation of the equipments are very important to know for an engineer. This course covers the fundamentals and practical applications for understanding of design and operation of the chiller and cooling tower. The comprehensive coverage of the basic theory, system analysis, optimization concept, and calculation methods to make this the most complete course available today in achieving an economical system.

A.MATERI

1.    Chiller System and Basics
a.    Work Principle of Chiller
b.    Piping Basics
c.    Pumping Basics
d.    Control Valve Basics
e.    Loop Control Basics
f.    Air-Cooled Chillers
g.    Water-Cooled Chillers
h.    Piping and Diversity
2.    Chiller Construction and Safety
a.    Dual Compressor Chillers
b.    VFD Chillers
c.    System Design Changes
d.    Mechanical Room Safety Standard
e.    Single Chiller System
3.    Basic Operation and Arrangement of Chiller
a.    Basic Components
b.    Series Chillers System
c.    Single Chiller Sequence of Operation
d.    Parallel Chiller System
e.    Parallel Chiller Sequence of Operation
f.    Series Counterflow Chillers
g.    Using VFD Chillers in Series Arrangements
h.    System Comparison
i.    Very Large Chiller Plants
j.    PrimarySecondary Sequence of Operation
4.    Chiller Cooling System
a.    Water-Side Free Cooling
b.    Direct Waterside Free Cooling
c.    Parallel Waterside Free Cooling
d.    Series Waterside Free Cooling
e.    Waterside Free Cooling Design Approach
f.    Waterside Free Cooling Sequence of Operation
g.    Chilled Water Volume
h.    Chilled Water Temperatures and Ranges
i.    Minimum Chilled Water Volume
j.    Estimating System Volume
k.    Evaluating System Volume
5.    Cooling Tower
a.    Cooling Tower Types and Cooling Tower Systems
b.    General Design Consideration
c.    Cooling Tower Construction and Installation Requirements
d.    Tower materials
e.    Cooling Tower Design and Operation Consideration
f.    Cooling Tower Water and Bleed-off Water Control
g.    Improving Energy Efficiency of Cooling Towers
6.    Hybrid Plants and Energy Saving
a.    Heat Recovery and Templifiers
b.    Load Profiles
c.    Heat Recovery Chillers
d.    Variable Primary Flow Design
e.    Variable Primary Flow Sequence of Operation
f.    Low Delta T Syndrome
g.    Low Delta T Example
h.    Low Delta T Syndrome Causes and Solutions

B.PESERTA
Technicians, ME engineers and other who responsible for selecting, mechanical equipments.

Jadwal Pelatihan Gemilang Training Tahun 2026 :

  • 7 – 8 Januari 2026
  • 11 – 12 Februari 2026
  • 4 – 5 Maret 2026
  • 8 – 9 April 2026
  • 6 – 7 Mei 2026
  • 10 – 11 Juni 2026
  • 8 – 9 Juli 2026
  • 5 – 6 Agustus 2026
  • 9 – 10 September 2026
  • 14 – 15 Oktober 2026
  • 4 – 5 November 2026
  • 2 – 3 Desember 2026
  • Catatan

 

Investasi dan Lokaspelatihan:

  • Yogyakarta, Hotel Neo Malioboro (7.500.000 IDR participant)
  • Jakarta, Hotel Amaris Tendean (7.500.000 IDR participant)
  • Bandung, Hotel Neo Dipatiukur (7.500.000 IDR participant)
  • Bali, Hotel Ibis Kuta(7.500.000 IDR participant)
  • Surabaya, Hotel Amaris, Ibis Style (7.500.000 IDR participant)
  • Lombok, Sentosa Resort (7.500.000 IDR participant)
  • Catatan : Apabila perusahaan membutuhkan paket in house training, anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan.

Fasilitas :

  • FREE Airport pickup service (Gratis Antar jemput HotelBandaraStasiunTerminal)
  • FREE Akomodasi Peserta ke tempat pelatihan .
  • Module Handout
  • FREE Flashdisk
  • Sertifikat
  • FREE Bag or bagpackers (Tas Training)
  • Training Kit (Dokumentasi photo, Blocknote, ATK, etc)
  • 2xCoffe Break & 1 Lunch, Dinner
  • FREE Souvenir Exclusive
  • Training room full AC and Multimedia